PUMPS & BACKUPS

SUMP PUMP INSTALLATION AND REPLACEMENT IN ST. PAUL, MN

ALSO SERVING MINNEAPOLIS, ST LOUIS PARK, AND ROSEVILLE, MN

  • Non-Clogging vortex impeller
  • 3/10 HP Premium 115V sump pump
  • Flows up to 43 gpm (163 lpm) per minute
  • Advanced switch technology allowing longer switch life (available in automatic only)
  • UL Listed 3-wire cord plug
  • Corrosion resistant powder coated epoxy finish
  • All cast iron construction for a more robust pump
  • Stainless steel hardware
  • No screens to clog
  • Watertight neoprene gasket between motor and pump housing
  • Motor – 60 Hz, 1550 RPM, oil-filled, hermetically sealed, automatic reset thermal overload protected
  • Upper and lower sleeve bearings running in bath of oil
  • Carbon and ceramic shaft seal
  • Maximum temperature for effluent or dewatering – 130°F (54°C)
  • Passes 1/2" inch spherical solids
  • 1 1/2" NPT Discharge
  • On point – 7 1/4"
  • Off point – 3"
  • 5 year warranty

Note: The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with non-automatic pumps.

MODEL 53 CAST IRON SERIES – 1/3 HP

  • 3-year warranty
  • 3/10 HP 115 V sump pump; 230 V also available
  • Performance up to 19.25' (5.9 m) 
  • Flows up to 43 GPM (163 LPM)
  • Cast iron case cover, base, motor and pump housing
  • Engineered thermoplastic base
  • Corrosion-resistant, powder coated epoxy paint

MODEL 98 CAST IRON SERIES – 1/2 HP

  • Non-clogging engineered plastic vortex impeller design
  • Corrosion resistant powder coated epoxy finish
  • Durable cast construction. Cast switch case, motor, pump housing and base. No sheet metal parts to rust or corrode
  • Castings – All cast iron class 25-30 25000# tensile strength
  • Stainless steel screws, guard, handle, arm and seal assembly
  • Float operated submersible (NEMA 6) 2-pole mechanical switch
  • Motor – Permanent split capacitor, 60 Hz, 1725 RPM, oil-filled, thermetically sealed, automatic reset thermal overload protection
  • Bearings – Upper & lower oil fed cast iron
  • Carbon and ceramic shaft seal
  • Entire unit pressure tested after assembly
  • Watertight neoprene ring between motor and pump housing
  • Maximum temperature for effluent or dewatering 130°F – 54°C
  • Passes ½ inch spherical solids
  • No screens to clog
  • Standard cord length 15 ft. (UL Listed)
  • 1½" NPT Discharge (1½" X 2" PVC Adapter included with BN & BE Models)
  • On point – 9½"
  • Off point – 3"
  • Major width – 10 1/8"
  • Height – 12"

Note: The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with non-automatic pumps.

Aquanot Spin 508

  • High-performance, high-efficiency, double-sealed pump
  • 2 days of battery protection (10% duty cycle), 5.5 hours continuous pump run
  • Can connect 2 independent switches for redundancy. Not just a single switch with 2 floats • Optional high water switch for alarm AND redundant pump run (purchase 10-4830)
  • Smart, innovative controller; premium built-in diagnostic logic; battery maintenance and alarms
  • Tests pump
  • Supervises switch connections
  • Monitors for the following alert conditions:
  • Pump activation
  • Pump, switch, battery, charger faults
  • Continuous run caused by stuck switch, blocked/frozen pipe, etc.
  • High water (optional)
  • Air locked pump
  • Power outage
  • Simple interface
Share by: